{{badge.Name}}

Perc Detector

{{resource("/ProductPage/Labels/StockNumber")}} {{displayVariant.DisplayCode}}
$134.95
{{resource("/ProductPage/Labels/List")}} $185.00

{{resource("/ProductPage/Labels/Sale")}} ${{displayVariant.Price.PurchasePrice | toDisplayFormat}}
{{resource("/ProductPage/Labels/Was")}} ${{displayVariant.Price.WasPrice | toDisplayFormat}}
{{resource("/ProductPage/Labels/List")}} ${{displayVariant.Price.ListPrice | toDisplayFormat}}
{{displayVariant.PromotionalText}}

{{resource("/ProductPage/Labels/Options")}}

{{displayVariant.InventoryStatus}} {{format(resource("/Shared/Label/EstimatedArrivalDate"),displayVariant.ShippingEstimate)}} {{format(resource("/Shared/Label/BackOrderedEstimatedArrivalDate"),displayVariant.ShippingEstimate)}}
{{errorMessage}}
{{resource("/ProductPage/Labels/VolumePricingHeader")}}
{{resource("/Shared/Label/QuantityTable/Qty")}}
{{volumePrice.Quantity}}+ {{resource("/Shared/Label/QuantityTable/Each")}}
{{volumePrice.Quantity}}+
{{resource("/Shared/Label/QuantityTable/Price")}} ${{volumePrice.Price.Amount | toDisplayFormat}}
{{resource("/Shared/Label/QuantityTable/Save")}}
{{volumePrice.Save | toDisplayFormat}}%

{{format(resource('/ProductPage/Labels/SoldInIncrementOf'),displayVariant.SoldInIncrements)}}

{{format(resource("/ProductPage/Labels/MinimumOrderQuantity"),displayVariant.MinimumOrderQuantity)}}

DETECT "PERC" LEAKS EASILY.

The perc detector is used to detect perc leaks easily. Includes a sensor, two D alkaline batteries, spare filters and a heavy-duty carrying case. When turned on, the detector begins to beep once per second. When perc is detected, a siren sound is emitted. Detects 25 parts per million.

Features

  • Heavy-duty and cordless
  • Features a convenient power indicator
  • 17" chrome plated flexible metal probe
  • Includes a carrying case and 2 "D" batteries

Product Specifications

Brand: TEK - Mate
Units: Each
Material: Various
How often do I need to change the filter on your perc detector?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
The answer to filter life is very subjective because it depends on how dirty of an environment the user is operating in. We recommend that operators visually inspect the tips and use their better judgment when to replace. Not replacing the filter will not harm the unit but it may reduce sensitivity.
Staff
  • logologo Staff
How long can I expect the sensor to last in your perc detector?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
The sensors have a stated life of 100 operating hours. Because our customers use the detector for a special application it will likely get two to three times that life. The reason is because Perc is a chlorine-based gas and testing with any chlorine-based gases the manufacturer was able to obtain well over 250 hours of life on the sensor. The sensor life is greatly reduced when detecting fluorine-based gases. We do carry the replacement sensors.
Staff
  • logologo Staff
Why did my perc detector take almost 15 minutes to start working. Is that normal?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
That would not be a normal warm-up time but it does happen occasionally. This occurrence is called “burning in” the sensor. Generally if it takes more than 1 minute to warm-up it is either the first time the unit has been turned on or it was left in an area with considerable moisture. The reason this happens is because the sensor is hydroscopic or wants water. The sensor is trying to burn out this moisture as it reaches its’ ready state (900 deg. F).
Staff
  • logologo Staff
Why does my Perc Detector not work?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
The most common reason a perc detector is not working when first put into use is because the sensor was not installed. The sensor is packaged separately in the case with the PD1 and the instructions note the sensor must be installed before using.
Staff
  • logologo Staff
Why would my Perc Detector make a constant high pitched noise?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
This occurrence is called “burning in” and usually happens when the unit has not been used for a period of time, or when installing a new sensor. This process can take up to 20 minutes. If it continues to emit this noise for longer than 20 minutes the unit maybe defective.
Staff
  • logologo Staff
How long will the battery in the Perc Detector last before needing to charge?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
About 16 hours.
Staff
  • logologo Staff
Do you provide Halogen Leak Detectors for Dry Cleaners to use for compliance with the new EPA Dry Cleaning This detector
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
This detector has been approved by the California Air resource Board and DLI.
Staff
  • logologo Staff
Why did my perc detector (PD1) take almost 15 minutes to start working. Is that normal?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
That would not be a normal warm-up time but it does happen occasionally. This occurrence is called “burning in” the sensor. Generally if it takes more than 1 minute to warm-up it is either the first time the unit has been turned on or it was left in an area with considerable moisture. The reason this happens is because the sensor is hydroscopic or wants water. The sensor is trying to burn out this moisture as it reaches its’ ready state (900 deg. F).
Staff
  • logologo Staff
Does your perc detector detect varying levels of perc or other vapors?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
No, this unit is not adjustable, it either detects or doesn’t.
Staff
  • logologo Staff
Do I need to have a Perc Detector on premises?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
If you are using Perc it is required that a perc detector be on premises to detect leaks. For further information on other requirements contact OSHA at 1-800-321-OSHA or www.osha.gov.
Staff
  • logologo Staff
What do I need to do with the “Perc” detector if a “siren” sound is detected before a leak is pinpointed?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
If the siren goes off- reset the unit. Resetting the unit gives the “Perc detector” a zero start reference. To rest the unit, take it out into some fresh air. Turn it off and then turn it back on. Please note: that the siren may alarm if the tip of the unit comes into contact with moisture or solvents. If this happens clean or replace the tip. Also note, the unit may also go off if a new battery is needed. Check the light on the unit- if the light is weak or blinking- it’s time for a new battery.
Staff
  • logologo Staff
What chemicals does the perc detector detect?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
The perc detector we carry detects other chemicals as well as perchloroethylene or “perc”. It detects refrigerant gas leaks in Air Conditioning and/or Refrigeration systems. These include CFC’s, HCFC’s, and HFC’s. It detects Ethylene Oxide gas leaks, SF-6 found in high voltage circuit breakers, Halon gases which are in fire extinguishing systems, and most other gases that contain Chlorine, Fluorine, and Bromine.
Staff
  • logologo Staff
What items do I need to have on premises in order to comply with OSHA regulations?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
The requirements vary from state to state. It is best to check on local compliance laws.
Staff
  • logologo Staff
Why does the Perc Detector beep continually?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
The Perc Detector that we carry will start to beep continually when it is turned on. This does not mean there is a leak. If the chemical leak is detected the beep changes to a “siren” sound.
Staff
  • logologo Staff
What does the Perc Detector come with?
Anonymous
Posting As
Please Note: Your answer will be displayed upon approval.
A:
The Perc Detector comes with the Perc Detector, 1- sensing tip, 1-sensor, 2- C batteries, instructions and a carrying case. There is extra room in the carrying case for a holster and 3-more sensing tips.
Staff
  • logologo Staff

No Results